BOILER AND SOLENOID VALVE ACTUATOR CONFIGURATION
GATEWAY CHILLER CONFIGURATION
GATEWAY FANCOIL CONFIGURATION
PROBES CONFIGURATION
99 ZONE CENTRAL UNIT CONFIGURATION
The 99 zone control unit item 3350
must be used to manage systems
with combination boiler. The
function is not in fact available on
the 4 zone control unit item HC/
HS/L/N/NT4695 and item AM5875.
boiler/Solenoid valve aCtuator
[ZA] [ZB1] [N1] [ZB2] [N2]
0 5 1 6 1
This device does not need physical
congurators but, to end the system
conguration operations, interact
with the “Congure zones” menu
and with TiThermo applications. For
these operations refer to the manual
supplied with the products.
Zone 1 probe
[ZA] [ZB] [SLA]
0 1 -
Zone 2 probe
[ZA] [ZB] [SLA]
0 2 -
Zone 3 probe
[ZA] [ZB] [SLA]
0 3 -
Zone 4 probe
[ZA] [ZB] [SLA]
0 4 -
Zonef1 Gateway
[ZA] [ZB] [N] [TYPE]
0 1 1 0
Zone 3 Gateway
[ZA] [ZB] [N] [TYPE]
0 3 1 0
Zone 2 Gateway
[ZA] [ZB] [N] [TYPE]
0 2 1 0
Zone 2 Gateway
[ZA] [ZB] [N] [TYPE]
0 4 1 0
Gateway CHiller
[ZA] [ZB] [N] [TYPE]
0 0 1 1