Energy management
99 ZONE CENTRAL UNIT
CONFIGURATION
The 99 zone control unit item 3350
must be used to use the magnetic
contact management function. The
function is not in fact available on
the 4 zone control unit item HC/
HS/L/N/NT4695 and item AM5875.
This device does not need physical
congurators but, to end the system
conguration operations, interact
with the “Congure zones” menu.
As an alternative the TiThermo
application can be used. For these
operations refer to the manual
supplied with the products.
REACTION
TIME
REACTIVATION
TIME
TiThermo screen
Temperature central unit
item 3550
REACTION TIME
The reaction time can be set from
0 to 2 minutes and is a sort of
delay to the deactivation of the
temperature control zone. During
this time the system completely
ignores the opening of the window
frame avoiding switching the
corresponding temperature control
zone OFF. Setting 0 minutes
deactivation is practically instant.
This function is suitable for short
openings of windows or doors not
WINDOW
CLOSED
WINDOW
OPENING
WINDOW
CLOSING
WINDOW
CLOSED
time can be set from
0 to 2 minutes
radiant panel ON radiant panel
kept ON
radiant panel
kept ON
radiant panel ON
When setting the parameters for
the management of the magnetic
contacts, the TiThermo application
must be used. Two parameters may
be set: the reaction time, and the
reactivation time.
needed for the changes of air, for
example opening a window to close
or open the shutters, or opening the
entrance door to welcome a person.